Project ID: plumID:19.080
Source: clch3cl/ch-fes/plumed.inp
Originally used with PLUMED version: 2.4.1
Stable: zipped raw stdout - zipped raw stderr - stderr
Master: zipped raw stdout - zipped raw stderr - stderr

Click on the labels of the actions for more information on what each action computes
tested onv2.10
tested onmaster
UNITSThis command sets the internal units for the code. More details LENGTHthe units of lengths=A TIMEthe units of time=fs ENERGYthe units of energy=kcal/mol

DISTANCECalculate the distance/s between pairs of atoms. More details ATOMSthe pair of atom that we are calculating the distance between=1,3 LABELa label for the action so that its output can be referenced in the input to other actions=d1
DISTANCECalculate the distance/s between pairs of atoms. More details ATOMSthe pair of atom that we are calculating the distance between=2,3 LABELa label for the action so that its output can be referenced in the input to other actions=d2

COMBINECalculate a polynomial combination of a set of other variables. More details ARGthe values input to this function=d1,d2 COEFFICIENTS the coefficients of the arguments in your function=1.0,-1.0 PERIODICif the output of your function is periodic then you should specify the periodicity of the function=NO LABELa label for the action so that its output can be referenced in the input to other actions=cv
UPPER_WALLSDefines a wall for the value of one or more collective variables, More details ARGthe arguments on which the bias is acting=d1,d2 ATthe positions of the wall=3.0,3.0 KAPPAthe force constant for the wall=100.0,100.0 LABELa label for the action so that its output can be referenced in the input to other actions=constrain
COORDINATIONCalculate coordination numbers. This action has hidden defaults. More details GROUPAFirst list of atoms=3 GROUPBSecond list of atoms (if empty, N*(N-1)/2 pairs in GROUPA are counted)=4 R_0The r_0 parameter of the switching function=1.10 NN The n parameter of the switching function =12 LABELa label for the action so that its output can be referenced in the input to other actions=dis1 COORDINATIONCalculate coordination numbers. This action has hidden defaults. More details GROUPAFirst list of atoms=3 GROUPBSecond list of atoms (if empty, N*(N-1)/2 pairs in GROUPA are counted)=5 R_0The r_0 parameter of the switching function=1.10 NN The n parameter of the switching function =12 LABELa label for the action so that its output can be referenced in the input to other actions=dis2 COORDINATIONCalculate coordination numbers. This action has hidden defaults. More details GROUPAFirst list of atoms=3 GROUPBSecond list of atoms (if empty, N*(N-1)/2 pairs in GROUPA are counted)=6 R_0The r_0 parameter of the switching function=1.10 NN The n parameter of the switching function =12 LABELa label for the action so that its output can be referenced in the input to other actions=dis3 COMBINECalculate a polynomial combination of a set of other variables. More details ARGthe values input to this function=dis1,dis2,dis3 COEFFICIENTS the coefficients of the arguments in your function=0.333,0.333,0.333 PERIODICif the output of your function is periodic then you should specify the periodicity of the function=NO LABELa label for the action so that its output can be referenced in the input to other actions=nm
EXTERNALCalculate a restraint that is defined on a grid that is read during start up This action has hidden defaults. More details ARGthe labels of the scalars on which the bias will act=nm FILEthe name of the file containing the external potential=extbias LABELa label for the action so that its output can be referenced in the input to other actions=external
bf1: BF_CHEBYSHEVChebyshev polynomial basis functions. More details MINIMUMThe minimum of the interval on which the basis functions are defined=-2.0 MAXIMUMThe maximum of the interval on which the basis functions are defined=2.0 ORDERThe order of the basis function expansion=48 td: TD_WELLTEMPEREDWell-tempered target distribution (dynamic). More details BIASFACTORThe bias factor used for the well-tempered distribution=30 # Expansion
VES_LINEAR_EXPANSIONLinear basis set expansion bias. This action has hidden defaults. More details ... ARGthe labels of the scalars on which the bias will act=cv BASIS_FUNCTIONSthe label of the one dimensional basis functions that should be used=bf1 TEMPthe system temperature - this is needed if the MD code does not pass the temperature to PLUMED=300 GRID_BINSthe number of bins used for the grid=800 TARGET_DISTRIBUTIONthe label of the target distribution to be used=td LABELa label for the action so that its output can be referenced in the input to other actions=b1 ... VES_LINEAR_EXPANSION
# Optimization algorithm
OPT_AVERAGED_SGDAveraged stochastic gradient decent with fixed step size. This action has hidden defaults. More details ... BIASthe label of the VES bias to be optimized=b1 STRIDEthe frequency of updating the coefficients given in the number of MD steps=4000 LABELa label for the action so that its output can be referenced in the input to other actions=o1 STEPSIZEthe step size used for the optimization=0.25 FES_OUTPUThow often the FES(s) should be written out to file=5 BIAS_OUTPUThow often the bias(es) should be written out to file=1000 COEFFS_OUTPUT how often the coefficients should be written to file=1 TARGETDIST_STRIDEstride for updating a target distribution that is iteratively updated during the optimization=5 ... OPT_AVERAGED_SGD

FLUSHThis command instructs plumed to flush all the open files with a user specified frequency. More details STRIDEthe frequency with which all the open files should be flushed=2000 PRINTPrint quantities to a file. More details ARGthe labels of the values that you would like to print to the file=d1,d2,cv,b1.bias STRIDE the frequency with which the quantities of interest should be output=2000 FILEthe name of the file on which to output these quantities=colvar